PART SIZE: upto 575mm Long are processed vertical, upto 1100mm horizontal

Furnace sizes: 200Kg to 550 Kgs

Normalising is done by heating to austenitising temperatures under a protective (endothermic) atmosphere and then pulling load out of furnace into vestibule inside sealed quench furnaces to cool them before removal from furnace and exposure to air. This is done to prevent exposure to air to which can lead to oxidation and decarburisation.